All settings are made with a "setter" function.For example, the default setting for the first voltage input is number 1, the amplitude calibration is 100, and the phase error is 0.16° This would be set as:

EmonLibDB\_set\_vInput(1, 100, 0.16);
EmonLibDB_set_vInput(1, 100, 0.16);

Using the 3rd current input will need, for a 100 A c.t. an amplitude calibration of 100 (i.e. the c.t's rated current) and a phase error of 1.4°, which would be set as:

EmonLibDB\_set\_cInput(3, 100, 1.4);
EmonLibDB_set_cInput(3, 100, 1.4);

To link those together and read the power, set:

EmonLibDB\_set\_pChannel(3, 1);
EmonLibDB_set_pChannel(3, 1);

A list of all available setter functions, and a description of what they do, follows in the Application Interface sections.

### ​Extracting the data.

The function

EmonLibDB\_Ready( );
EmonLibDB_Ready( );

must be called very frequently inside **loop( )**. If no new data is ready, this returns immediately with the value **false**. If however new data is ready, it returns the value **true** and you may then use the "getter" functions to retrieve the data. For example, to retrieve the real power measured on channel 3 (CT3 & Voltage 1 in the example above) and

assign the value to the floating point variable power3, you would use:

power3 = EmonLibDB\_getRealPower(3);
power3 = EmonLibDB_getRealPower(3);

A list of all available getter functions, and a description of what they do, follows in the Application Interface sections.