wfcooke commented Oct 9, 2024

If I set
show_all_bad_values = true
in sat_vapor_pres_nml I expect to see reports of locations of bad temperatures in my stdout. I do not.

The issue is that the output line
e.g.

write(iunit,'(a,e10.3,a,i4,a,i6)') 'Bad temperature=',temp(i),' at i=',i,' pe=',mpp_pe()

uses stdout as the output unit.
stdout is only defined for root pe

If I use stderr instead at

stdoutunit = stdout()

I get the output I need.
For readability stdoutunit should probably be changed to stderrunit (and set to stderr) in the sat_vapor_pres codeset.